Xbpi protocol [xbpi port, Asycom protocol [asycom, Pr 5230 instrument manual commissioning – Rice Lake PR5230 Fieldbus Transmitter User Manual
Page 143
PR 5230 Instrument Manual
Commissioning
Sartorius
EN-143
xBPI protocol [xBPI Port]
To configure the serial interfaces, press
-[Serial ports parameter]-[ xBPI-Port]
to select a RS-485 or RS-232 interface.
Press
to select the specific parameter.
Press
to select the s respective values.
The light gray displayed parameter cannot be changed.
Setup/
Serial ports
Printer
Slot1 RS232
Remote display
Builtin RS232
JBUS/MOD-Bus
-none-
SMA
-none-
xBPI-Port
Slot1..RS485
Click [Param].
Param
Only the baud rate and the stop bits are adjustable; the other parameters are fixed.
Setup/Serial ports/
Slot1 RS485
Assigned to
xBPI-Port
Baudrate
9600 bd 9600, 19200
Bits
8
Parity
odd
Stopbits
1 1, 2
Asycom protocol [Asycom]
To configure the serial interfaces, press
-[Serial ports parameter]-[Asycom] to select a RS-485 interface.
Press
to select the specific parameter.
Press
to select the respective values.
The light gray displayed parameter cannot be changed.
Setup/Serial ports/
Builtin RS485
Assigned to
Asycom
Protocol
Asycom V1 Select V1, V2 or V3*
Baudrate
9600 bd 300, 600, .... 19200
Bits
8 7, 8
Parity
even
Stopbits
1
Slave
A Select A - Z
* V1 = for old communication programs
V2 = for recipe controller
V3 = for OPC