Description of the I/O Area (Read / Write Window)

Input Area
Data transmission from the master to the PR 5230 (slave) is via the input area.
Weight or data requests are transmitted to the slave by the master.
The master has write access; the slave has read access.

Byte Name

Description

0

Write_Value (MSB)

e.g. limit value

1

:::

"

2

:::

"

3

Write_Value (LSB)

"

4

Read_Value_Select

e.g. gross weight

5

Write_Value_Select

Write:

Limit 1 On

6

free

Res M3 Res M2 Res M1 free

Set M3 Set M2 Set M1

Free/digital outputs

7

Get
FixTare

Set
FixTare

Res
Power

Res Test Set

Test

Res
Tare

Set
Tare

Set Zero

Control byte,

response to

0->1

transition

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0


The

control byte

activates the corresponding action in the instrument with a set bit.

After execution of the operation, the bit should be reset.

Variable

Function

Write_Value

The weight value is transmitted as a binary 32-bit value with plus or minus sign
Data type:

DINT

Read_Value_Select For selecting the value sent by the instrument
Write_Value_Select For selecting the function to be executed by the instrument
GetFixTare

The gross weight is copied into the fixtare memory.

SetFixTare

Taring is performed using the value stored in the fixtare memory.

ResPower

The

Power_Fail

bit in the output area is deleted.

ResTest

The test operating mode is finished.

SetTest

The test operating mode is started. Now the test value can be read out by reading the
gross weight.

ResTare

Tare is reset.

SetTare

The scale is tared.

SetZero

The scale is set to zero.

Res M1…3

Marker 1…3 is reset

Set M1…3

Marker 1…3 is set