10 ethernet cfm commands, 1 ethernet cfm enable – CANOGA PERKINS 9175 Command Reference User Manual

Page 158

Advertising
background image

CanogaOS Command Reference

10-1

10 Ethernet CFM Commands

Default Ethernet CFM Configuration
Ethernet CFM is globally disabled.
By default, all interface ports are transparent to CFM messages (that is,they treat CFM
messages as any other message).
There are no MEPs or MIPs configured.
Restrictions for CFM
噝 CFM is not supported and cannot be configured on routed ports, linkagg port channel

or ports that belong to a linkagg port.

噝 You cannot configure CFM on VLAN interfaces.
噝 Down MEPs cannot be configured on the CE/CN ports. The configuration is

allowed, but does not take affect.

10.1 ethernet cfm enable

Use this command to enable CFM funcation. Use the no parameter to disable the CFM funcation on the

bridge.

Command Syntax

ethernet cfm enable

no ethernet cfm enable

Command Mode

Configure mode

Default

no ethernet cfm enable

Usage

This command is used to enable CFM globally.

Examples

Switch#configure terminal

Switch(config)# ethernet cfm enable

Switch#configure terminal

Switch(config)# no ethernet cfm enable

Related Commands

no ethernet cfm enable

Advertising