10 ethernet cfm commands, 1 ethernet cfm enable – CANOGA PERKINS 9175 Command Reference User Manual
Page 158
CanogaOS Command Reference
10-1
10 Ethernet CFM Commands
Default Ethernet CFM Configuration
Ethernet CFM is globally disabled.
By default, all interface ports are transparent to CFM messages (that is,they treat CFM
messages as any other message).
There are no MEPs or MIPs configured.
Restrictions for CFM
噝 CFM is not supported and cannot be configured on routed ports, linkagg port channel
or ports that belong to a linkagg port.
噝 You cannot configure CFM on VLAN interfaces.
噝 Down MEPs cannot be configured on the CE/CN ports. The configuration is
allowed, but does not take affect.
10.1 ethernet cfm enable
Use this command to enable CFM funcation. Use the no parameter to disable the CFM funcation on the
bridge.
Command Syntax
ethernet cfm enable
no ethernet cfm enable
Command Mode
Configure mode
Default
no ethernet cfm enable
Usage
This command is used to enable CFM globally.
Examples
Switch#configure terminal
Switch(config)# ethernet cfm enable
Switch#configure terminal
Switch(config)# no ethernet cfm enable
Related Commands
no ethernet cfm enable