4 ethernet oam max-rate, 5 ethernet oam link-monitor on, Ethernet oam link-monitor on – CANOGA PERKINS 9175 Command Reference User Manual

Page 175

Advertising
background image

CanogaOS Command Reference

11-3

Usage

Set the timer to emit at least one OAMPDU per second and ensure that the sublayer adheres to the

maximum number of OAMPDUs per second. The minimum is 1 OAMPDU per second and the maximum

is 10 OAMPDU per second

Examples

Switch# configure terminal

Switch (config)# interface eth-0-1

Switch (config-if)# ethernet oam min-rate 1

11.4 ethernet oam max-rate

Use this command to set the OAMPDU maximum number of PDUS per second. Use the no

form of the command to reset max-rate to the default value.

Command Syntax

ethernet oam max-rate PDUS

no ethernet oam max-rate

PDUS The maximum number of PDUs per second in the range <1-10>

Command Mode
Interface mode

Default

The default value of the max-rate is 10 PDUs per second.

Usage
This command is to ensure that the sublayer adheres to the maximum number of
OAMPDUs per second. The minimum is 1 OAMPDU per second and the maximum is 10
OAMPDUs per second.

Examples
Examples
Switch # configure terminal
Switch (config)# interface eth1
Switch (config-if)# ethernet oam max-rate 10

11.5

ethernet oam link-monitor on

Use this command to turn on link monitoring on an interface. Use the no form of this
command to turn link monitoring off.

Advertising