12 cfm linktrace tests – CANOGA PERKINS 9175 Command Reference User Manual

Page 165

Advertising
background image

CanogaOS Command Reference

10-8

Usage

1

˅This command is used to transmit a loopback message for a MAC address to a remote MP for fault

verification.

2

˅This command is used to transmit a loopback message to a remote MEP for fault

verification.

Examples

Switch#

loopback ethernet mpid 88 level 7 vlan 30

Switch#

loopback ethernet 8908.0909.1267 level 7 vlan 30 repeat 5 timeout 5

Related Commands

10.12 CFM linktrace tests

Use the procedures in this section to issue CFM path trace messages and to discover the path to a remote

MEP.

Command Syntax

linktrace ethernet MAC (domain DOMAIN | level LEVEL) vlan VLANID

(ttl TTL|)

( timeout TIMEOUT|)

linktrace ethernet mep MEPID (domain DOMAIN | level LEVEL) vlan VLANID

(ttl TTL|)

( timeout TIMEOUT|)

Command Mode

Privileged Exec mode

Default

The default TTL is 64.

The default timeout is 10 seconds.

Usage

1

˅This command is used to transmit a loopback message for a MAC address to a remote

MEP for Path discovery.

2

˅This command is used to transmit a loopback message to a remote MEP for Path

discovery.

Examples

Switch#

linktrace ethernet mep 88 level 7 vlan 30 ttl 64 timeout 5

Switch#

linktrace ethernet 3456.0908.0908 level 7 vlan 30 ttl 64 timeout 5

Advertising