CanogaOS Command Reference

10-5

Switch(config)#spanning-tree max-age 12

Related Commands

10.7 Configuring a RMEP archive hold time

Use this command to configure the number of minutes that data from a missing remote maintenance end

point (mep) is kept before it is purged.

Command Syntax

ethernet cfm mep archive-hold-time minutes

Command Mode

Configure mode

Default

The default is 5 minutes. The value in the range 1 to 65535 minutes.

Usage

None

Examples

Switch#configure terminal

Switch(config)# ethernet cfm mep hold-time 60

Related Commands

10.8 Configure per MA continuity check (cc) parameters

Use the command to define continuity check parameters for an MA.

Command Syntax

ethernet cfm cc enable level LEVEL vlan VLAN_ID

no ethernet cfm cc enable level LEVEL vlan VLAN_ID