Show alarms – Carrier Access Adit 3000 Series and Multi-Service Router (MSR) Card none User Manual
Page 31
Adit 3000 (Rel. 1.6) and MSR Card (Rel 2.0) CLI
2-7
User Mode
show alarms
Use the show alarms command to display the active alarms.
Syntax:
> show alarms [t1
port|lcc number]
{alert|all|critical|info|major|minor}
Example:
Adit 3500> show alarms all
Alarm Severity Time
Alarm LOS T1 4 Major Jan 1 00:00:08 2007
Alarm LOS T1 3 Major Jan 1 00:00:08 2007
Alarm PRI T1 2 - Line NOT Ready Major Jan 1 00:00:08 2007
Supported Platforms:
Adit 3104, Adit 3200, Adit 3500, MSR
Field
Definition
t1 port
Display alarms for a specific port.
Adit 3104: Value must be 1.
Adit 3500: Range = 1-4.
lcc number
Display alarms for a specific Link Cross-Connect (LCC).
MSR: Range = 1-8.
alert
Filter alert alarms (threshold crossing).
all
Display all alarms.
critical
Filter critical alarms.
info
Filter information alarms.
major
Filter major alarms.
minor
Filter minor alarms.