redundancy rollback-timer
Use the Voice Service SIP redundancy rollback-timer command to set the interval of time between
the time the primary proxy fails, and when a rollback is performed back to the primary proxy. To disable
rollback timer, see no redundancy rollback-timer command on page 25-10.
Syntax:
(config-voice-serv-sip)# redundancy rollback-timer
number
Example:
(config-voice-serv-sip)# redundancy rollback-timer 300
Supported Platforms:
Adit 3104, Adit 3500, MSR
redundancy secondary-address
Use the Voice Service SIP redundancy secondary-address command to configure the secondary
outbound proxy.
Syntax:
(config-voice-serv-sip)# redundancy secondary-address
address
Example:
(config-voice-serv-sip)# redundancy secondary-address
192.168.100.140
Supported Platforms:
Adit 3104, Adit 3500, MSR
Field
Definition
number
Range 60 - 3600 seconds, or 0 (disabled), with a default of 300
(5 min).
Field
Definition
address
Enter the IP address of the secondary outbound proxy.