Redundancy rollback-timer, Redundancy secondary-address – Carrier Access Adit 3000 Series and Multi-Service Router (MSR) Card none User Manual

Page 475

Advertising
background image

Adit 3000 (Rel. 1.6) and MSR Card (Rel 2.0) CLI

25-15

Configuration - Voice Service SIP Mode

redundancy rollback-timer

Use the Voice Service SIP redundancy rollback-timer command to set the interval of time between
the time the primary proxy fails, and when a rollback is performed back to the primary proxy. To disable
rollback timer, see no redundancy rollback-timer command on page 25-10.

Syntax:

(config-voice-serv-sip)# redundancy rollback-timer

number

Example:

(config-voice-serv-sip)# redundancy rollback-timer 300

Supported Platforms:

Adit 3104, Adit 3500, MSR

redundancy secondary-address

Use the Voice Service SIP redundancy secondary-address command to configure the secondary
outbound proxy.

Syntax:

(config-voice-serv-sip)# redundancy secondary-address

address

Example:

(config-voice-serv-sip)# redundancy secondary-address

192.168.100.140

Supported Platforms:

Adit 3104, Adit 3500, MSR

Field

Definition

number

Range 60 - 3600 seconds, or 0 (disabled), with a default of 300
(5 min).

Field

Definition

address

Enter the IP address of the secondary outbound proxy.

Advertising