ELECTRICAL DATA

85

86

87

Unit Data

DCF092TX-18HVVW

DCF094TX-18HVWW

DCF096TX-18HWWW

Nominal Run Amps

(1)

A

583.4

595.6

607.9

Maximum Start Amps

A

818.7

830.9

843.2

Recommended Mains Fuse Size

A

630

630

630

Evaporator
Immersion Heater Rating

W

250

250

250

Condenser Fan - Per Fan (AC)
Quantity

18

18

18

Full Load Amps

A

2.5

2.5

2.5

Locked Rotor Amps

A

8.8

8.8

8.8

Motor Rating

kW

1.3

1.3

1.3

Condenser Fan - Per Fan (EC)
Quantity

18

18

18

Full Load Amps

A

3.9

3.9

3.9

Motor Rating

kW

2.6

2.6

2.6

Compressor - Per Compressor
Nominal Run Amps

A

55.2 / 55.2 / 59.2

55.2 / 59.2 / 59.2

59.2 / 59.2 / 59.2

Quantity

3 + 3 + 3

3 + 3 + 3

3 + 3 + 3

Motor Rating

kW

33.1 / 33.1 / 36.2

33.1 / 36.2 / 36.2

36.2 / 36.2 / 36.2

Sump Heater Rating

W

140

140

140

Start Amps

(2)

A

267 / 267 / 298

267 / 298 / 298

298 / 298 / 298

OPTIONAL EXTRAS
Power Factor Correction (PF 0.98)

(3)

Nominal Run Amps

A

531.6

545.7

559.8

Reactive power reduction/saving

(4)

kVAr

87.5

85.2

82.9

Maximum Start Amps

A

766.9

781.0

795.1

Recommended Mains Fuse Size

A

630

630

630

Electronic Soft-start
Nominal Run Amps

A

583.4

595.6

607.9

Maximum Start Amps

A

699.5

711.7

724.0

Recommended Mains Fuse

A

630

630

630

Power Factor Correction (PF 0.98)

& Electronic Soft Start

(3)

Nominal Run Amps

A

531.6

545.7

559.8

Maximum Start Amps

A

647.7

661.8

675.9

Recommended Mains Fuse Size

A

630

630

630

Standard Head Pump (Single or Run/Standby)
Pump Full Load Amps

A

28.5

28.5

28.5

Unit Nominal Run Amps

A

611.9

624.1

636.3

Recommended Mains Fuse Size

A

630

670

670

Motor Rating

kW

16.4

16.4

16.4

Larger Head Pump (Single or Run/Standby)
Pump Full Load Amps

A

35.0

35.0

35.0

Unit Nominal Run Amps

A

618.4

630.6

642.8

Recommended Mains Fuse Size

A

670

670

670

Motor Rating

kW

20.3

20.3

20.3

Standard Head Inverter Pump (Single or Run/Standby)
Pump Full Load Amps

A

26.9

26.9

26.9

Unit Nominal Run Amps

A

604.5

616.8

629.2

Recommended Mains Fuse Size

A

630

670

670

Motor Rating

kW

16.8

16.8

16.8

Larger Head Inverter Pump (Single or Run/Standby)
Pump Full Load Amps

A

33.2

33.2

33.2

Unit Nominal Run Amps

A

609.5

621.8

634.2

Recommended Mains Fuse Size

A

670

670

670

Motor Rating

kW

20.7

20.7

20.7

(1) Based upon 7.2°C Evap / 54.4°C Condensing, AC Standard Fans.
(2) Starting amps refers to the direct online connections.
(3) For unit RLA values at alternative power factor values contact Airedale.
(4) Projected reactive power reduction based on a 0.95PF billing threshold.

DCF Electrical Data Extra Quiet