Unit Data
DCC082TR-19GYYV
DCC084TR-20GYVV
DCC087TR-21GVVV
Nominal Run Amps
(1)
A
555.1
584.3
613.8
Maximum Start Amps
A
783.5
812.7
822.2
Recommended Mains Fuse Size
A
630
630
670
Evaporator
Immersion Heater Rating
W
250
250
250
Condenser Fan - Per Fan (AC)
Quantity
19
20
21
Full Load Amps
A
4.3
4.3
4.3
Locked Rotor Amps
A
15.0
15.0
15.0
Motor Rating
kW
2.0
2.0
2.0
Condenser Fan - Per Fan (EC)
Quantity
19
20
21
Full Load Amps
A
3.9
3.9
3.9
Motor Rating
kW
2.6
2.6
2.6
Compressor - Per Compressor
Nominal Run Amps
A
47.5 / 47.5 / 55.2
47.5 / 55.2 / 55.2
55.2 / 55.2 / 55.2
Quantity
3 + 3 + 3
3 + 3 + 3
3 + 3 + 3
Motor Rating
kW
29.6 / 29.6 / 33.1
29.6 / 33.1 / 33.1
33.1 / 33.1 / 33.1
Sump Heater Rating
W
140
140
140
Start Amps
(2)
A
287 / 287 / 267
287 / 267 / 267
267 / 267 / 267
OPTIONAL EXTRAS
Power Factor Correction (PF 0.98)
(3)
Nominal Run Amps
A
505.8
526.1
546.5
Reactive power reduction/saving
(4)
kVAr
83.1
95.9
108.6
Maximum Start Amps
A
734.2
754.5
754.9
Recommended Mains Fuse Size
A
630
630
670
Electronic Soft-start
Nominal Run Amps
A
555.1
584.3
613.8
Maximum Start Amps
A
668.7
697.9
715.4
Recommended Mains Fuse
A
630
630
670
Power Factor Correction (PF 0.98)
& Electronic Soft Start
(3)
Nominal Run Amps
A
505.8
526.1
546.5
Maximum Start Amps
A
619.4
639.7
648.1
Recommended Mains Fuse Size
A
630
630
670
Standard Head Pump (Single or Run/Standby)
Pump Full Load Amps
A
11.2
11.2
11.2
Unit Nominal Run Amps
A
566.2
595.5
625.0
Recommended Mains Fuse Size
A
630
630
670
Motor Rating
kW
6.2
6.2
6.2
Larger Head Pump (Single or Run/Standby)
Pump Full Load Amps
A
21.2
21.2
21.2
Unit Nominal Run Amps
A
576.2
605.5
635.0
Recommended Mains Fuse Size
A
630
630
670
Motor Rating
kW
12.1
12.1
12.1
Standard Head Inverter Pump
(Single or Run/Standby)
Pump Full Load Amps
A
10.2
10.2
10.2
Unit Nominal Run Amps
A
563.0
592.2
621.6
Recommended Mains Fuse Size
A
630
630
670
Motor Rating
kW
6.4
6.4
6.4
Larger Head Inverter Pump (Single or Run/Standby)
Pump Full Load Amps
A
19.8
19.8
19.8
Unit Nominal Run Amps
A
570.6
599.7
629.0
Recommended Mains Fuse Size
A
630
630
670
Motor Rating
kW
12.4
12.4
12.4
(1) Based at 7.2°C Evap / 54.4°C Condensing, AC Standard Fans.
(2) Starting amps refers to the direct on line connections.
(3) For unit RLA values at alternative power factor values contact Airedale.
(4) Projected reactive power reduction based on a 0.95PF billing threshold
DCC Electrical Data - Regular Quiet