Chillers deltachill™ air cooled and freecool, Te ch ni ca l, Air c oo led – Airedale DeltaChill FreeCool 110kW - 1080kW User Manual

Page 250: Dcc electrical data - extra quiet

Advertising
background image

250

Chiller Technical Manual 7267818 V1.4.0_04_2014

Te

ch

ni

ca

l

Chillers

DeltaChill™ Air Cooled and FreeCool

A

ir C

oo

led

ELECTRICAL DATA

158

159

160

Unit Data

DCC070TX-14GPYY

DCC055DX-15DYV0

DCC059DX-16DVV0

Nominal Run Amps

(1)

A

461.4

363.1

390.6

Maximum Start Amps

A

696.7

591.5

599.0

Recommended Mains Fuse Size

A

500

400

450

Evaporator
Immersion Heater Rating

W

250

170

170

Condenser Fan - Per Fan (AC)
Quantity

14

15

16

Full Load Amps

A

2.5

2.5

2.5

Locked Rotor Amps

A

8.8

8.8

8.8

Motor Rating

kW

1.3

1.3

1.3

Condenser Fan - Per Fan (EC)
Quantity

14

15

16

Full Load Amps

A

3.9

3.9

3.9

Motor Rating

kW

2.6

2.6

2.6

Compressor - Per Compressor
Nominal Run Amps

A

59.2 / 47.5 / 47.5

47.5 / 55.2

55.2 / 55.2

Quantity

2 + 3 + 3

3 + 3

3 + 3

Motor Rating

kW

36.2 / 29.6 / 29.6

29.6 / 33.1

33.1 / 33.1

Sump Heater Rating

W

140

140

140

Start Amps

(2)

A

298 / 287 / 287

287 / 267

267 / 267

OPTIONAL EXTRAS
Power Factor Correction (PF 0.98)

(3)

Nominal Run Amps

A

430.9

333.4

352.7

Reactive power reduction/saving

(4)

kVAr

54.3

50.9

62.9

Maximum Start Amps

A

666.2

561.8

561.1

Recommended Mains Fuse Size

A

500

400

450

Electronic Soft-start
Nominal Run Amps

A

461.4

363.1

390.6

Maximum Start Amps

A

577.5

476.7

492.2

Recommended Mains Fuse

A

500

400

450

Power Factor Correction (PF 0.98)

& Electronic Soft Start

(3)

Nominal Run Amps

A

430.9

333.4

352.7

Maximum Start Amps

A

547.0

447.0

454.3

Recommended Mains Fuse Size

A

500

400

450

Standard Head Pump (Single or Run/Standby)
Pump Full Load Amps

A

11.2

8.9

11.2

Unit Nominal Run Amps

A

472.4

371.7

401.8

Recommended Mains Fuse Size

A

500

400

450

Motor Rating

kW

6.2

4.4

6.2

Larger Head Pump (Single or Run/Standby)
Pump Full Load Amps

A

21.2

11.2

11.2

Unit Nominal Run Amps

A

482.4

374.2

401.8

Recommended Mains Fuse Size

A

500

400

450

Motor Rating

kW

12.1

6.1

6.1

Standard Head Inverter Pump

(Single or Run/Standby)
Pump Full Load Amps

A

10.2

7.3

10.2

Unit Nominal Run Amps

A

469.6

368.8

398.6

Recommended Mains Fuse Size

A

500

400

450

Motor Rating

kW

6.4

4.5

6.4

Larger Head Inverter Pump (Single or Run/Standby)
Pump Full Load Amps

A

19.8

10.1

10.1

Unit Nominal Run Amps

A

477.3

371.1

398.5

Recommended Mains Fuse Size

A

500

400

450

Motor Rating

kW

12.4

6.3

6.3

(1) Based at 7.2°C Evap / 54.4°C Condensing, AC Standard Fans.
(2) Starting amps refers to the direct on line connections.
(3) For unit RLA values at alternative power factor values contact Airedale.
(4) Projected reactive power reduction based on a 0.95PF billing threshold

DCC Electrical Data - Extra Quiet

Advertising
This manual is related to the following products: