Page 230: Dcc electrical data - regular quiet

Advertising
background image

230

Chiller Technical Manual 7267818 V1.4.0_04_2014

Te

ch

ni

ca

l

Chillers

DeltaChill™ Air Cooled and FreeCool

A

ir C

oo

led

DCC Electrical Data - Regular Quiet

98

99

100

Unit Data

DCC047DR-08EPV0

DCC049DR-08EYY0

DCC049DR-10EPV0

Nominal Run Amps

(1)

A

333.9

334.5

342.1

Maximum Start Amps

A

569.2

571.1

577.4

Recommended Mains Fuse Size

A

355

355

400

Evaporator
Immersion Heater Rating

W

170

170

170

Condenser Fan - Per Fan (AC)
Quantity

8

8

10

Full Load Amps

A

4.3

4.3

4.3

Locked Rotor Amps

A

15.0

15.0

15.0

Motor Rating

kW

2.0

2.0

2.0

Condenser Fan - Per Fan (EC)
Quantity

8

8

10

Full Load Amps

A

3.9

3.9

3.9

Motor Rating

kW

2.6

2.6

2.6

Compressor - Per Compressor
Nominal Run Amps

A

59.2 / 55.2

47.5 / 47.5

59.2 / 55.2

Quantity

2 + 3

3 + 3

2 + 3

Motor Rating

kW

36.2 / 33.1

29.6 / 29.6

36.2 / 33.1

Sump Heater Rating

W

140

140

140

Start Amps

(2)

A

298 / 267

287 / 287

298 / 267

OPTIONAL EXTRAS
Power Factor Correction (PF 0.98)

(3)

Nominal Run Amps

A

301.9

311.5

308.0

Reactive power reduction/saving

(4)

kVAr

53.1

40.7

56.2

Maximum Start Amps

A

537.2

548.1

543.3

Recommended Mains Fuse Size

A

355

355

400

Electronic Soft-start
Nominal Run Amps

A

333.9

334.5

342.1

Maximum Start Amps

A

450.0

456.3

458.2

Recommended Mains Fuse

A

355

355

400

Power Factor Correction (PF 0.98)

& Electronic Soft Start

(3)

Nominal Run Amps

A

301.9

311.5

308.0

Maximum Start Amps

A

418.0

433.3

424.1

Recommended Mains Fuse Size

A

355

355

400

Standard Head Pump (Single or Run/Standby)
Pump Full Load Amps

A

8.9

8.9

8.9

Unit Nominal Run Amps

A

342.5

343.0

350.8

Recommended Mains Fuse Size

A

400

400

400

Motor Rating

kW

4.4

4.4

4.4

Larger Head Pump (Single or Run/Standby)
Pump Full Load Amps

A

11.2

11.2

11.2

Unit Nominal Run Amps

A

345.0

345.5

353.2

Recommended Mains Fuse Size

A

400

400

400

Motor Rating

kW

6.1

6.1

6.1

Standard Head Inverter Pump

(Single or Run/Standby)
Pump Full Load Amps

A

7.3

7.3

7.3

Unit Nominal Run Amps

A

339.5

340.3

347.7

Recommended Mains Fuse Size

A

400

400

400

Motor Rating

kW

4.5

4.5

4.5

Larger Head Inverter Pump (Single or Run/Standby)
Pump Full Load Amps

A

10.1

10.1

10.1

Unit Nominal Run Amps

A

341.7

342.6

349.9

Recommended Mains Fuse Size

A

400

400

400

Motor Rating

kW

6.3

6.3

6.3

(1) Based at 7.2°C Evap / 54.4°C Condensing, AC Standard Fans.
(2) Starting amps refers to the direct on line connections.
(3) For unit RLA values at alternative power factor values contact Airedale.
(4) Projected reactive power reduction based on a 0.95PF billing threshold