Chillers deltachill™ air cooled and freecool, Te ch nic al, Fre ec oo l – Airedale DeltaChill FreeCool 110kW - 1080kW User Manual
Page 97: Dcf mechanical data - regular quiet
![background image](/manuals/370937/97/background.png)
97
Chiller Technical Manual 7267818 V1.4.0_04_2014
Te
ch
nic
al
Chillers
DeltaChill™ Air Cooled and FreeCool
Fre
eC
oo
l
1
2
3
DCF046DR-07DXY0
DCF048DR-07DPY0
DCF051DR-08DPV0
FreeCooling
Y
Y
Y
Enhance Capital Allowance
N
N
N
Number of Refrigeration Circuits
2
2
2
Cooling Duty - High Airflow EC Fans
Nominal Output - Mechanical
(1)
kW
477.9
492.2
523.0
Nominal Input - Mechanical
kW
169.5
172.7
180.0
EER
(2)
2.69
2.72
2.77
ESEER
4.23
4.08
4.09
SEER
4.06
3.93
3.94
Nominal Output - Free Cooling
kW
355.0
358.0
400.8
Ambient temperature for 100% Free Cooling
(5)
°C
-1.2
-1.6
-0.7
Cooling Duty - EC Fans
Nominal Output - Mechanical
(1)
kW
474.8
488.9
520.1
Nominal Input - Mechanical
kW
168.9
172.1
179.2
EER
(2)
2.68
2.71
2.77
ESEER
4.22
4.07
4.08
SEER
4.05
3.92
3.93
Nominal Output - Free Cooling
kW
347.2
350.0
392.2
Ambient temperature for 100% Free Cooling
(5)
°C
-1.5
-1.8
-1
Cooling Duty - AC Fans
Nominal Output - Mechanical
(1)
kW
465.0
478.4
510.0
Nominal Input - Mechanical
kW
171.0
174.2
180.8
EER
(2)
2.60
2.63
2.69
ESEER
3.97
3.87
3.86
SEER
3.82
3.73
3.73
Nominal Output - Free Cooling
kW
324.1
326.3
366.6
Ambient temperature for 100% Free Cooling
(5)
°C
-2.3
-2.6
-1.8
Capacity Steps
%
15-35-50-70-85-100
25-45-65-85-100
25-45-60-80-100
Minimum Turndown Ratio
0.16
0.25
0.23
Dimensions (H x W x L)
mm
2682 x 2200 x 4846
2682 x 2200 x 4846
2682 x 2200 x 4846
Weight
Machine
(3)
kg
4465
4345
4450
Operating
kg
5055
4930
5060
Water Volume (Total Internal)
l
590
585
610
Maximum Waterflow
l/s
35.1
35.1
35.1
Minimum Waterflow
l/s
8.0
13.4
13.4
Face Area (Total)
m²
2.38
2.38
2.38
Nominal Airflow - High Airflow EC Fans
m³/s
42.8
42.8
48.9
Nominal Airflow - EC Fans
m³/s
41.1
41.1
47.0
Nominal Airflow - AC Fans
m³/s
36.6
36.6
41.8
Quantity
7
7
8
Maximum Speed - High Airflow EC Fans
rpm
1080
1080
1080
Maximum Speed - EC Fans
rpm
1026
1026
1026
Maximum Speed - AC Fans
rpm
904
904
904
Compressor
Trio + Trio
Tandem + Trio
Tandem + Trio
Quantity of Compressors
6
5
5
Oil Charge Volume (Total)
l
3 x 5.3 + 3 x 5.3
2 x 5.3 + 3 x 5.3
2 x 5.3 + 3 x 5.3
Refrigeration
Charge (Total)
kg
24 + 30
24 + 31
24 + 34
Water Inlet / Outlet - Unit
DN125
DN125
DN125
Water Drain / Bleed - Evap
inch
0.5
0.5
0.5
Water System
Minimum System Water Volume
(4)
l
1424
2216
2216
Maximum System Operating Pressure
Bar
10
10
10
DCF Mechanical Data - Regular Quiet
(1)
Based on units performance at 15/10°C return/supply temperatures, 35°C ambient, 20% Ethylene Glycol
(2)
EER = DX Cooling Output / (Compressor input power + Fan Input Power),
(3)
Based on standard unit without options, operating weight includes refrigerant charge and water volume.
For unit weights with waterside options fitted please refer to Airedale.
(4)
For minimum system volume, refer to Design Features & Information - Minimum System Water Volume Calculations
(5)