Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual

Page 112

Advertising
background image

7–6

Communicating with an SLC on a DH-485 Network

Publication 2755-6.8

Connecting Readers to SLC 5/04 Controller – 1 AIC Module

The SLC 5/04 controller requires two 1747-PIC converters.
However, you can use an RJ48 Y adapter (8-wire LAN phone jack
plug) to connect the two 1747-PIC modules. The RJ48 Y adapter is
a modular adapter for 4-pair cable which parallels two 4-pair jacks
and one 4-pair modular plug. This adapter eliminates the second
1747-AIC module shown on the previous page.

The end devices on a DH-485 network must be terminated. The
wiring base of the AdaptaScan Reader provides a termination switch.

SLC 5/04 Processor

Term
A
B
Com
Shield
Chassis Gnd

1747-PIC

1747-AIC Module

1747-PIC

AdaptaScan Wiring Base

RS-422/RS-485 Terminal

AdaptaScan Wiring Base

RS-422/RS-485 Terminal

Computer

DH-485

RS-232

RS-232

DH-485

Channel 0

RJ48 Y Adapter

(8-wire LAN Phone Jack Plug)

Available from Anixter Company

Part No: Hubbell BR851-B

Phone: 414-355-0222

Power

Supply

Advertising