Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual

Page 187

Advertising
background image

10–25

Communicating with an SLC 5/03 Processor on a DeviceNet Network using Explicit Messaging

Publication 2755-6.8

Explicit Message Program Control Feature

DeviceNet
drop line

DeviceNet trunk line

Master’s Explicit
Request

Slave’s Explicit
Response

1203-GK5
Communication
Adapter

MC0 file transfer (including words 224-255)
(sent from processor to scanner module)

MC1file transfer (including words 224-255)
(sent from scanner module to processor)

Explicit Message – A message used to transmit
commands, data, requests for data or
responses. The message is sent from a client
on the DeviceNet network to a server on that
network.

Request – An explicit message sent by a client
to a server requesting the server to perform
a function.

Response – An explicit message sent by a
server to a client in response to the client’s
request. For every request issued, there is a
response.

4

1305 AC
drive

5

MC1 file transfer
is completed. TXID’s
are deleted and can be
reused.

AdaptaScan
Bar Code
Reader

1. Format an M0 file transfer in the processor to send an Explicit

Message Request to the scanner module (download).

2. The scanner module transmits the Explicit Message Request to

the slave device over the DeviceNet network.

3. The slave device transmits the Explicit Message Response back

to the scanner and is queued into a file transfer buffer.

4. The processor uses an M1 file transfer to retrieve the Explicit

Message Response from the scanner’s buffer (upload).

5. Format an M0 file transfer with a Delete Response Command and

the current transaction ID read in step 4. The transaction IDs are
deleted and can be reused.