14–3

Communicating with a 2760-RB Module on a DH-485 Network

Publication 2755-6.8

Enhanced PLC-5 Processor DIP Switches

witch

Switch Lever #

Switch #

1

2

3

4

5

6

7

8

9

10

SW-1

on

on

on

on

on

on

on

on

on

off

SW-2

on

on

on

off

off

on

on

off

on

off

I/O Chassis Backplane DIP Switches

Switch Lever #

1

2

3

4

5

6

7

8

off

off

off

off

off

on

off

off

2760-RB Module DIP Switches

witch

Switch Lever #

Switch #

1

2

3

4

5

6

7

8

SW-1

off

off

off

off

off

off

off

off

SW-2

off

off

off

off

off

off

off

off

SW-3

off

off

off

off

ot

licable

SW-4

off

off

on

off

Not Applicable

The 2760-RB module is placed in the 1771 chassis in slot 0 next to
the PLC. For this application, the AdaptaScan Reader communicates
through port 1 on the 2760-RB. A 1771-ASB module can also be
used to communicate with the 2760-RB module over the chassis
backplane to Remote I/O.

Flexible Interface Module

(Catalog No. 2760-RB)

Protocol Cartridge