Related publications, Connecting to the devicenet network, Connecting a power supply to the reader – Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual

Page 142

Advertising
background image

9–2

Communicating with an SLC 5/03 Processor on a DeviceNet

t

Network

Publication 2755-6.8

Related publications include:

Publication

Description

2755-837

AdaptaScan Bar Code Readers User Manual

2755-838

AdaptaScan Software User Manual

1787-6.5.3

DeviceNet Manager Software Manual

1747-6.5.2

1747-SDN DeviceNet Scanner Configuration Manual

In addition, you may want to refer to the SLC 500 Hardware and
Software User Manuals.

The following illustration shows the nodes of the DeviceNet
master/slave network. You must terminate the first and last node in
the network. Refer to the 1747-SDN DeviceNet Scanner
Configuration Manual
(Publication No. 1747-6.5.2) for more
information regarding user termination information.

Computer

1770-KFD
DeviceNet

Interface Box

AdaptaScan

Bar Code Reader

SLC 5/03 Processor

1747-SDN DeviceNet Scanner

1787-MGR DeviceNet Manager Software
SLC 500 Advanced Programming Software
2755-ASN AdaptaScan Software

Node 62

DeviceNet Trunk Cable

Node 1

DeviceNet Trunk Cable

Node 3

The following illustration shows how to connect a 2755-PW46 or
-PW47 power supply to a single bar code reader.

Use a shielded cable (Belden 9316 recommended) to make the
connections. Connect the shield to the ground screw on the reader’s
wiring base.

V-

24V+

Ground Screw
on Wiring Base

Reader

2755-PW46

Power Supply

Note: Use a termination switch for DeviceNet in the wiring base for
the end of the network.