Overview, Hardware requirements, Software requirements – Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual

Page 201: Chapter

Advertising
background image

Chapter

11

Publication 2755-6.8

Communicating with a PLCĆ5

Processor on a DeviceNet

Network

This application describes how to connect and configure an
AdaptaScan Bar Code Reader to communicate with a PLC-5
processor over a DeviceNet network in a master/slave mode. A 4
character Interleaved 2 of 5 bar code symbol is used in this
application.

The DeviceNet network has the following nodes:

AdaptaScan Bar Code Reader on node 3

1771-SDN DeviceNet Scanner on node 1

Computer running DeviceNet Manager Software on node 62

The DeviceNet terminal block in the reader’s wiring base connects
the AdaptaScan Reader to the DeviceNet network. The wiring base
has two DeviceNet terminal blocks; one for upstream connection and
one for downstream connection.

The hardware items required for this application are:

2755-SN3, -SN5 or -SN8 AdaptaScan Bar Code Reader

2755-NB40 or -NB41 Wiring Base

2755-PW46 or -PW47 Power Supply

2755-NC43 or -NC48 Configuration Cable

1771-SDN Scanner Module (v3.04 firmware or later)

1770-KFD DeviceNet RS-232 Interface

DeviceNet trunk cable

1771 I/O chassis

PLC-5 processor

Computer running Windows 3.1 (or later) or Windows 95

9-to-25 Pin Adapter (for Computer with 25-pin COM port)

The software requirements for this application are:

2755-ASN AdaptaScan Offline Programming Software (v8.0 or
later)

6200 Series Programming Software

1787-MGR DeviceNet Manager Software (v3.0 or later)

Overview