10–13

Communicating with an SLC 5/03 Processor on a DeviceNet Network using Explicit Messaging

Publication 2755-6.8

This section shows how to configure the AdaptaScan Bar Code
Reader using the AdaptaScan Software (Catalog No. 2755-ASN).

The procedures in this section show how to:

scan/decode 4 character, Interleaved 2 of 5 bar code symbols

define a DeviceNet address

configure the scanner

trigger the decoder

configure the format of messages and the message destination

Create a New Project

Create a new project named SLC DeviceNet for one AdaptaScan Bar
Code Reader (Bar Code Reader 1).

1. Choose New from the Project menu to create a new project.

2. Click the New button to add a bar code reader (Bar Code Reader

1) to the project.

3. Choose Edit from the Project menu to rename the project SLC

DeviceNet.

If you need to change the baud rate, proceed to the next section.
If you do not need to change the baud rate, proceed to step 4.

Configuring the Reader