Communicating with an SLC 5/03 Processor on a DeviceNet Network using Explicit Messaging

Publication 2755-6.8

Data Table File 0 Monitor

Below is a partial listing of the File 0 data table. The table shows
that bit O:1/0 is set to enable run mode in the 1747-SDN Scanner
(1=RUN; 0=IDLE).

1747-SDN to AdaptaScan Interface

Data Table

Processor File :MASTER.ACH

Data Table File O

Address

Data (Radix = ASCII)

O:1

\00\01

O:1.1

\00\00

O:1.2

\00\00

O:1.3

\00\00

O:1.4

\00\00

O:1.5

\00\00

O:1.6

\00\00

O:1.7

\00\00

O:1.8

\00\00

O:1.9

\00\00

O:1.10

\00\00

O:1.11

\00\00

O:1.12

\00\00

O:1.13

\00\00

O:1.14

\00\00

O:1.15

\00\00

Data Table File M1 Monitor

Below is a partial listing of the M1 data table.

M1:1.1 contains the DeviceNet status bit

M1:1.2 is the byte count (4) of a message

M1:1.3 to M1:1.4 is data 0300 from the AdaptaScan Reader

1747-SDN to AdaptaScan Interface

Data Table

Processor File :MASTER.ACH

Data Table File M1:1

Address

Data (Radix = ASCII)

M1:1

\00\00

M1:1.1

\80\01

M1:1.2

\00\04

M1:1.3

3 0

M1:1.4

0 0

M1:1.5

\00\00

M1:1.6

\00\00

M1:1.7

\00\00

M1:1.8

\00\00

M1:1.9

\00\00

M1:1.10

\00\00

M1:1.11

\00\00

M1:1.12

\00\00

M1:1.13

\00\00

M1:1.14

\00\00

M1O:1.15

\00\00