Example bar code string = 0300 – Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual

Page 78

Advertising
background image

4–22

Downloading Match Codes via DH485 Protocol with an SLC 5/03

t

or SLC 5/04

t

Controller

Publication 2755-6.8

Place the Match Code Hex command (Byte Swapped) in the
Destination File Address N7:90.

example bar code string = 0300

0300 converted to hex = 30333030

ASCII Hex command = 3F10CE010003040030333030

Byte Location

0

1

2

3

4

5

Byte Swapped

N7:90

103F

01CE

0300

0004

3330

3030

You can verify whether or not a correct match code was downloaded
by placing a bar code label in front of the reader so that it is scanned.
Observe the Output LED’s on the top of the reader. When the
downloaded match code matches a scanned label, the Output 1 will
turn on, otherwise Output 2 will turn on (for no read or no match).

Viewing Match Code Downloads in Slave Mode via Ladder Logic

Use the following SLC ladder logic for DH485 Slave Mode if the
AdaptaScan I/O LEDs cannot be used for viewing.

Read/Write

Read/Write:

Type:

Target Device:

Local/Remote:

Control Block:

Control Block Length:

MSG

WRITE

PEER-TO-PEER

485CIF

LOCAL

N7:200

14

B3

1

]

[

Read/Write

Read/Write:

Type:

Target Device:

Local/Remote:

Control Block:

Control Block Length:

MSG

READ

PEER-TO-PEER

485CIF

LOCAL

N7:50

14

B3

0

]

[

Note: You can only initiate one read or one write at a time. Reads