Configuring the reader – Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual
Page 153

9–13
Communicating with an SLC 5/03 Processor on a DeviceNet
t
Network
Publication 2755-6.8
This section shows how to configure the AdaptaScan Bar Code
Reader using the AdaptaScan Software (Catalog No. 2755-ASN).
The procedures in this section show how to:
•
scan/decode 4 character, Interleaved 2 of 5 bar code symbols
•
define a DeviceNet address
•
configure the scanner
•
trigger the decoder
•
configure the format of messages and the message destination
Create a New Project
Create a new project named DeviceNet Master/Slave for one
AdaptaScan Bar Code Reader (Bar Code Reader 1).
1. Choose New from the Project menu to create a new project.
2. Click the New button to add a bar code reader (Bar Code Reader
1) to the project.
3. Choose Edit from the Project menu to rename the project
DeviceNet Master/Slave.
If you need to change the baud rate, proceed to the next section.
If you do not need to change the baud rate, proceed to step 4.
Configuring the Reader