Related publications, Connecting a power supply to the reader, Connecting to the dh-485 network – Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual

Page 58

Advertising
background image

4–2

Downloading Match Codes via DH485 Protocol with an SLC 5/03

t

or SLC 5/04

t

Controller

Publication 2755-6.8

Related publications include:

Publication

Description

2755-837

AdaptaScan Bar Code Readers User Manual

2755-838

AdaptaScan Software User Manual

1747-6.2

SLC 500

t Modular Hardware Style Installation and

Operation Manual

9399-APSUM-11.15.95

Advanced Programming Software User Manual

The following illustration shows how to connect a 2755-PW46 or
-PW47 power supply to a single bar code reader.

Use a shielded cable (Belden 9316 recommended) to make the
connections. Connect the shield to the ground screw on the reader’s
wiring base.

V-

24V+

Ground Screw
on Wiring Base

Reader

2755-PW46

Power Supply

The wiring base of the AdaptaScan Reader has an RS-485/RS-422
terminal block for point-to-point or network connections.

This section shows three connection options:

Connecting readers to SLC 5/03

Connecting readers to SLC 5/04 using two 1747-AIC Modules

Connecting readers to SLC 5/04 using one 1747-AIC Module

Note: You can use the 1761-NET-AIC Advanced Interface
Converter in place of the 1747-AIC Module.

Important:

The DH485 network cable requires proper shielding,
grounding and termination. Refer to Data
Highway/Data Highway Plus/Data Highway DH485
Cable Installation Manual (Publication 1770-6.2.2).

Related Publications

Connecting a Power
Supply to the Reader

Connecting to the DH-485
Network

Advertising