Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual

Page 93

Advertising
background image

5–11

Communicating with a 1746-BAS BASIC Module

Publication 2755-6.8

2. Configure the serial port as follows:

From the Protocol list box, select Terminal

From the Connection list box, select RS232

The configuration must match the host configuration.

3. Click Save and then Close to return to the main Project dialog.

Create a Message

Data sent from the AdaptaScan Reader to the BASIC module uses
messages.

1. Click the Message button from the main Project dialog.

2. Under Triggered By, check the Enable check box.

3. Under Device, select Bar Code Reader 1.

4. Under Input, select [Decoder].

5. Click the New button to create a message field.

6. Under Symbol Source, select Bar Code Reader 1.

7. Under Bar Code Labels & Symbols, select Symbol 1.