Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual
Page 263
![background image](/manuals/580474/263/background.png)
13–9
Communicating with a 2760-RB Module over an RS-232 Link
Publication 2755-6.8
6. Select option 11: Configuration parameters. Set to:
MODEM CONTROL (ENABLE/DISABLE)=DISABLE
9600 BITS PER SECOND (YES/NO)=YES
8 BITS NO PARITY (YES/NO)=YES
XON/XOFF (ENABLE/DISABLE)=DISABLE
RS232 (YES/NO)=YES
RECEIVE MATRIXING (ENABLE/DISABLE)=ENABLE
BYTE SWAPPING (ENABLE/DISABLE)=DISABLE
BINARY DATA NO CONVERSIONS (YES/NO)=YES
HDR/TLR ON OUTPUT (ENABLE/DISABLE)=ENABLE
HEADER BYTE LENGTH (DEC 0...4)= 0
HEADER DATA[0](HEX 0...FF)=0
HEADER DATA[1](HEX 0...FF)=0
HEADER DATA[2](HEX 0...FF)=0
HEADER DATA[3](HEX 0...FF)=0
TRAILER BYTE LENGTH (DEC 0...4)=2
TRAILER DATA[0](HEX 0...FF)=0d
TRAILER DATA[1](HEX 0...FF)=0a
TRAILER DATA[2](HEX 0...FF)=0
TRAILER DATA[3](HEX 0...FF)=0
Type save or quit to exit out of the editor.
7. Verify that the 2760-RB is in chassis 0, group 0 module 0.
8. Save the above configuration.