Set output timer command set output timer response, Led status response – Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual

Page 56

Advertising
background image

3–17

Downloading Match Codes from a Host Device

Publication 2755-6.8

Set Output Timer Command

Set Output Timer Response

Packet Contents

Data Sent

Packet Contents

Response

DeviceNet Address

3F*

DeviceNet Address

3F

Set Attribute Request

10

Set Attribute Response

90

Class

D0

Instance Number (LSB)

02

Instance Number (MSB)

00

Attribute Number - Max Time

09

Data (LSB)

FA

Data (MSB)

00

*3F = Address 63, modify as required
** Time in milliseconds

LED Status Response

Data at Indicated Bit Address = LED State

Byte

Bits

LED Indicator

0 = Off

1 = Yellow

2 = Green

3 = Red

4 = Not

Used

5 = Flash

Yellow

6 = Flash

Green

7 = Flash

Red

0

0-2

I/O 1

OFF

ON

0

3-5

I/O 2

OFF

ON

1

0-2

TRIGGER / READ

No

Trigger

Triggered

Valid

Read

1

3-5

ON SYMBOL

Not Read-

ing

Reading

Read

<100%

0-2

LASER ON

OFF

ON

2

3-5

MODULE

No Power

Device

OK

Hardware

Fault

Power Up

Minor

Fault

3

0-2

NETWORK

DeviceNet

OK

DeviceNet

Fault

Estab-

lished

No

Response

3

3-5

Advertising