Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual

Page 306

Advertising
background image

16–3

Communicating with AdaptaScan Bar Code Readers via DeviceNet Peer-to-Peer Protocol

Publication 2755-6.8

Reader 2

Reader 3

Reader 1

Other

DeviceNet

Devices

24V+

V-

24V+

V-

24V+

V-

Ground Screw
on Wiring Base

Ground Screw
on Wiring Base

Ground Screw
on Wiring Base

Ground Screw
on Wiring Base

Ground V- at
One Place

See DeviceNet Cable System Planning and Installation Manual
(Publication No. DN-6.7.1) for recommendations and accessories.

Multiple Reader Connections using Other Power Supply

Below all readers are powered by another power supply. Use a linear
unregulated power supply. The supply must provide 14 watts of
power to each reader. Use a shielded cable (Belden 9316
recommended) when making power connections.

Note: You must ground V- to Earth Ground at a single point on the
power supply link, preferably as near the power supply as possible.

User

Specified

Unregulated

Linear Power

Supply

Reader 2

Reader 3

Reader 1

V-

V+

Other

DeviceNet

Devices

Ground

Screw

Ground V- at
One Place

See DeviceNet Cable System Planning and Installation Manual
(Publication No. DN-6.7.1) for recommendations and cable
accessories.

Advertising