15–12

Downloading Match Codes via DH485 using a PLC-5 Processor and a 2760-RB Module

Publication 2755-6.8

Configure the Serial Port

1. Click the Serial Port button from the Project dialog.

2. Configure the serial port as follows:

Check (enable) the Scanner Protocol check box

From the Protocol list box, select DH-485

From the Baud Rate list box, select 19,200

From the Connection list box, select RS485

The configuration must match the host configuration.

3. Click the Edit button under Protocol to edit the DH-485

parameters.

Edit the parameters as follows:

Select Slave under Master/Slave

From the Node list box, select 2

This is the node address of the reader on the network.

4. Click OK to return to the Serial Port dialog.

5. Click Save and then Close to return to the main Project dialog.