16–8
Communicating with AdaptaScan Bar Code Readers via DeviceNet Peer-to-Peer Protocol
Publication 2755-6.8
Configure the Decoder Trigger
Bar Code Reader 1 is triggered by its own package detect device.
Refer to Publication No. 2755-837 for other input sources that trigger the
decoder.
1. Click the Decoder button from the main Project dialog.
2. Under Triggered By, select Package Detect from the Input list.
3. Click the Save button.
4. Click the Close button and return to the main Project dialog.
Configure the Serial Port
Configure the parameters of the serial port to match the host device.
1. Click the Serial Port button from the main Project dialog.
2. Verify that the serial port settings match the host device.
3. Click Save and then the Close button to return to the Project
dialog.