Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual
Page 332

17–10
Communicating with PanelView 900
t
Terminals on a DeviceNet Network
Publication 2755-6.8
10. Edit the following parameters.
Specify
To
Interscan Delay
Provide a delay between scans of the
Explicit-Client tags. Enter a value of 0 to 65535
milliseconds. The default is 500 msec. This time
delay is inserted between each full scan of the
Explicit-Client tags in the current screen context.
Note: Time delays of less than 500 msec should
be carefully considered since the Explicit-Client
mode will generate low priority network
messaging at this interval.
Bus-off Interrupt
Specify what occurs when a Bus-off interrupt
occurs on the network:
Hold in Reset holds the PanelView and waits for
communications to be reset.
Reset and Continue Communications resets
DeviceNet communications and attempts to
re-establish the communications link (if possible).
11. Click Apply to save the settings.
12. Click OK to exit and return to the Terminal Setup dialog.