4. Double-click the 1747-SDN Scanner Module to open the

1747-SDN Module Configuration dialog.

From this dialog, you modify all configuration parameters for the
1747-SDN Scanner.

If you are using an AdaptaScan with v7.0 firmware on a network
with 2 or less nodes, change the Interscan Delay parameter to
20 ms. This will allow the AdaptaScan more CPU time to
process bar code data instead of responding to DeviceNet polls.

5. Click the Edit Scan List button.

Note: Version 8.0 of the AdaptaScan Offline Programming
Software and firmware minimizes DeviceNet polling interruption
of scanning.