8–10

Communicating with a PLC-5

R

over an RS-232 or RS-422 Link

Publication 2755-6.8

Create a Message

The Message dialogs define the format and content of message data
sent to the host by the reader when bar codes are decoded.

1. Click the Message button from the main Project dialog.

2. Under Triggered By, check the Enable check box.

3. Under Device, select Bar Code Reader 1.

4. Under Input, select [Decoder].

5. Click the New button to define a message field.

6. Under Symbol Source, select Bar Code Reader 1.

7. Under Bar Code Labels & Symbols, select Symbol 1.

8. Check (enable) the Match Exactly check box.