Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual

Page 338

Advertising
background image

17–16

Communicating with PanelView 900

t

Terminals on a DeviceNet Network

Publication 2755-6.8

Field

Description

Valid Characters

Notes

Array Size

The size of the array

character arrays are 1-128
characters

bit arrays are 1-16 bits

the array size must be an integer.

do not use blanks, tabs, carriage returns,
non-printable characters

Description

The description of the tag

Maximum characters = 255

any printable

do not use tabs, carriage returns, non-printable
characters

you can type the information in this field, or use
the description editor.

Address

➀➁

(I/O Slave and
Explicit-Server
Messages Only)

Specifies the data sent to and
from a remote device.
A remote address has the
following format:

I: <word> / <bit>
O: <word> / <bit>

Note: /<bit> is required for Bit
and Bit Array.

Maximum characters = 32
For more information on valid
addresses, refer to your
processor’s user manual.

I specifies input data
generated by the PanelView
and sent to a remote device.

O specifies output data
received by the PanelView
from a remote device.

do not use blanks, tabs, carriage returns,
non-printable characters

Initial Value

The starting value for the
current tag in engineering
units (used only for write
tags).

Maximum characters = 24

0 - 9

e, E, +, - and period

if the Data Type is bit, enter
either 0 or 1

do not use blanks, tabs, carriage returns,
non-printable characters

maximum precision is 6 places to the right of the
decimal point for non-floating point values

if present, a sign (+ or -) for the number must be
first (+ is the default)

if present, a sign for the exponent must
immediately follow the e or E

provides a preset value for numeric entry objects
only

no entry = default of 0

Scaling

Scale:
‘m’ in y = mx + b
Offset:
‘b’ in y = mx + b

The values you want to use
to convert the current tag’s
processor integer value (‘x’)
to engineering units (‘y’)

Maximum characters = 12

0 - 9

e, E, +, - and period

do not use blanks, tabs, carriage returns,
non-printable characters

maximum precision for scale is 6 places to right of
decimal point

maximum precision for offset is 6 places to right of
decimal point

if present, a sign (+ or -) for the number must be
first (+ is default)

if present, a sign for the exponent must
immediately follow the e or E

Data Entry Limits

Minimum
Maximum

The minimum and maximum
values that can be assigned
to the tag

Maximum characters = 12

0 - 9

e, E, +, - and period

do not use blanks, tabs, carriage returns,
non-printable characters

maximum precision is 6 places to the right of the
decimal point

if present, a sign (+ or -) for the number must be
first (+ is the default)

if present, a sign for the exponent must
immediately follow the e or E

Required fields for the Table View

Required fields for the Form View

These fields appear only when the data type is 4BCD, signed integer, unsigned
integer, IEEE Float.