12–12

Communicating with a PLC-5 Processor on a DeviceNet Network using Explicit Messaging

Publication 2755-6.8

This section shows how to configure the AdaptaScan Bar Code
Reader using AdaptaScan Software (Catalog No. 2755-ASN).

The procedures in this section show how to:

scan/decode 4 character, Interleaved 2 of 5 labels

define a DeviceNet address

configure the scanner

configure the decoder trigger

configure the format of messages and the message destination

Create a New Project

Create a new project named PLC DeviceNet Master/Slave for one
AdaptaScan Bar Code Reader (Bar Code Reader 1).

1. Choose New from the Project menu to create a new project.

2. Click the New button to add a bar code reader (Bar Code Reader

1) to the project.

3. Choose Edit from the Project menu to rename the project PLC

DeviceNet Master/Slave.

If you need to change the baud rate, proceed to the next section.
If you do not need to change the baud rate, proceed to step 4.