Plc-5 compatibility, Connecting the rb module to the reader, Classic plc-5 processor dip switches – Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual

Page 272

Advertising
background image

14–2

Communicating with a 2760-RB Module on a DH-485 Network

Publication 2755-6.8

Refer to the following table for hardware compatibility in this
application example.

th following

with the following PLC-5 type

Use the following 2760-RB
Interface Module type

PLC-5, -15, -25, etc.

New Generation PLC-5
(Series A, Rev. C or above)

Series A, Rev. G or below

Refer to the sample PLC-5

Refer to the sample PLC-5
program on page 14–5.
(Set BT compatibility bit
S26/4 while in program
mode.)

Series A, Rev. H or above

Refer to the sample PLC-5
program on page 14–5.

Refer to the sample PLC-5
program on page 14–6.
(Add ladder logic using IIN
update of RB. BTR must be
before BTW.)

The 2760-RB configuration example includes sample configuration
screens and DIP switch settings needed to establish communication
with the AdaptaScan Reader via DH-485.

Dip Switch Side View

Switch pushed toward
bottom (on position).

Switch pushed toward
top (off position).

Classic PLC-5 Processor DIP Switches

witch

Switch Lever #

Switch #

1

2

3

4

5

6

7

8

SW-1

on

on

on

on

on

on

on

off

SW-2

on

on

on

on

on

on

on

off

SW-3

on

on

off

off

Not Applicable

PLC-5 Compatibility

Connecting the RB Module
to the Reader