Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual

Page 23

Advertising
background image

1–6

Using the Auto-Load Function

Publication 2755-6.8

Configure the Decoder

1. Click the Decoder button from the main Project dialog.

2. Under Triggered By, select Package Detect from the Input list.

3. Click the Save button.

4. Click the Close button and return to the main Project dialog.

Configure the Discrete Input Module

The application uses a discrete input module to trigger the
Auto-Load function. The following procedure defines one of the
two input/output modules available in the AdaptaScan Bar Code
Reader as an input.

1. Click the Input/Output button on the main Project dialog.

2. Under Inputs & Outputs, select Discrete Input/Output 2. This is

the location of the 2755-IB5S DC Input Module in the reader’s
wiring base.

3. Under Use As, select Input.

4. Click the Save button.

5. Click the Close button to return to the main Project dialog.

Advertising