Rockwell Automation 2755-SNx Adaptascan Bar Code Readers User Manual

Page 26

Advertising
background image

1–9

Using the Auto-Load Function

Publication 2755-6.8

6. Click the Output To button to open the Package Outputs dialog.

7. Under Available Outputs, select Discrete Input/Output 1.

8. Click the Add>> button to add this selection under Output To:

Note: Discrete Input/Output 2 does not appear as an Available
Output because it was previously defined as an input.

9. Click OK until you return to the Match Table dialog.

Configure the Auto-Load Trigger Source

The application uses a discrete input module (Discrete Input/Output
2) to activate the Auto-Load function. The following procedure
shows how to configure the input which will activate Auto-Load.

1. Click the AutoLoad button from the Match Table dialog.

2. Under Auto-Load Trigger:

check the Enable check box.

select Bar Code Reader 1 from the Device list.

select Discrete Input/Output 2 from the Input list.

3. Click OK to return to the Match Table dialog.

4. Click Save and then Close to return to the Project dialog.