Using the Auto-Load Function
Publication 2755-6.8
6. Click the Output To button to open the Package Outputs dialog.
7. Under Available Outputs, select Discrete Input/Output 1.
8. Click the Add>> button to add this selection under Output To:
Note: Discrete Input/Output 2 does not appear as an Available
Output because it was previously defined as an input.
9. Click OK until you return to the Match Table dialog.
Configure the Auto-Load Trigger Source
The application uses a discrete input module (Discrete Input/Output
2) to activate the Auto-Load function. The following procedure
shows how to configure the input which will activate Auto-Load.
1. Click the AutoLoad button from the Match Table dialog.
2. Under Auto-Load Trigger:
•
check the Enable check box.
•
select Bar Code Reader 1 from the Device list.
•
select Discrete Input/Output 2 from the Input list.
3. Click OK to return to the Match Table dialog.
4. Click Save and then Close to return to the Project dialog.