Electronic Data Sheet (EDS) File Error Messages

Message

Recommended Action

The DeviceNet Data Type (#) is unsupported by PanelView. Use of this
parameter may produce unexpected results.

There is no corresponding PV Data Type for the DeviceNet
parameter that was chosen. Use of this parameter requires
knowledge of how the DeviceNet data is structured. For
instance, one element of the DeviceNet Time Data Type may
be displayed, but the location of the internal fields must be
known.

The DeviceNet Data Type (#) does not match the PanelView Data Type
chosen. It is recommended that either Bool or Bit Array is chosen.

Bool or Bit Array corresponds most closely to the parameter
chosen.

The DeviceNet Data Type (#) does not match the PanelView Data Type
chosen. It is recommended that either Signed or Unsigned Integer is chosen.
Display value scaling may be necessary.

Signed or Unsigned Integer corresponds most closely to the
parameter chosen.

The DeviceNet Data Type (#) does not match the PanelView Data Type
chosen. It is recommended that Floating Point is chosen.

Floating Point corresponds most closely to the parameter
chosen.

The DeviceNet Data Type (#) does not match the PanelView Data Type
chosen. It is recommended that Char Array is chosen.

Character Array corresponds most closely to the parameter
chosen.

This parameter designates that extended precision scaling should be used to
display the parameter. PanelView does not support extended precision scaling.

The chosen parameter specifies Extended Precision Scaling.
The appropriate scaling factor must be manually determined
and entered into the Scale and Offset fields on the Tag Form.

In order to support scaling, the PV Data Type will be changed to Unsigned
Integer.

The chosen parameter has scaling factors. To support scaling
factors, an appropriate PV Data Type must be chosen. The
scaling factor will be calculated and entered as the Scale and
Offset values on the Tag Form.

Unable to open EDS File.

The system was unable to open the specified EDS file.

Invalid EDS File.

The EDS file is corrupt or contains too many parameters to be
read.

Could not allocate memory.

The system is unable to allocate enough memory to read the
EDS file.