Communicating with an SLC 5/03 Processor on a DeviceNet

t

Network

Publication 2755-6.8

Configure the Decoder Trigger

To test the application, use the Timer to trigger the reader’s decoder.

1. Click the Decoder button from the main Project dialog.

2. Under Triggered By, select Timer from the Input list.

3. Click the Save button.

4. Click the Close button and return to the main Project dialog.

Create a Message

Defines the content of messages sent from the reader to the
1747-SDN Scanner after bar codes have been decoded.

1. Click the Message button from the main Project dialog.

2. Under Triggered By, check the Enable check box.

3. Under Device, select Bar Code Reader 1.

4. Under Input, select [Decoder].