TCP: Used by GV Ask service.
9010
TCP: Used by GV License Manager.
9012
TCP: Used by GV Metadata. Not visible on a configuration page.
9014
TCP: Used by GV Resolver. Not visible on a configuration page.
9016
TCP: Used by GV RulesWizard. Not visible on a configuration page.
9018
TCP: Used by GV RulesWizard. Not visible on a configuration page.
9019
TCP: Used by GV Transfer Manager.
9020
TCP: Used by GV Asset Manager.
9022
TCP: Used by GV Asset Manager.
9023
TCP: Used by GV Subscription Manager.
9024
TCP: Used by GV Proxy MDI.
9110
TCP: Used by GV NTFS MDI.
9115
TCP: Used by GV DIVA MDI.
9122
TCP: Used by GV FlashNet MDI.
9124
TCP: Used by GV Profile MDI. The service manages one host process for each
managed Profile. These host processes require ports 9130-9139. Stopping/starting
the service stops/starts all of the host processes.
9130
TCP: Used by GV MSeries MDI. The service manages one host process for each
managed M-Series iVDR. These host processes require ports 9140 - 9149.
Stopping/starting the service stops/starts all of the host processes.
9140
TCP: Used by GV News Share MDI.
9150
TCP: Used by GV K2 MDI and GV K2 Summit MDI Service. The service manages
a number of host processes, one for each K2 system that is being managed. These
9160
host processes require ports 9160 - 9169. Stopping/starting the service stops/starts
all of the host processes.
TCP: Used by GV FTP MDI in the Aurora workflow, which can use a range of
ports, starting with this port number.
9170
TCP: Used by XMOS Server incoming and outgoing MOS communication.
10540
Protocol: TCP. Used by SDB Server incoming, and by GV STRATUS and Aurora
Playout clients outgoing.
10541
TCP: Used by Ingest Router Port.
12345
Protocol: UDP. Used for live streaming from K2 Summit/Solo systems. This is the
default base for UDP ports, with the range being 31820 to 31827. Other ranges are
possible, depending on the UDP port base configured on the K2 Summit/Solo system.
31820
HTTP/TCP: Used by Grass Valley K2 Config for K2Config application connection
between a control point PC and the K2 system device configured. Used for most
functions.
49168
TCP: Used by Grass Valley K2 Config for K2Config application connection between
a control point PC and the K2 system device configured. Used for a few functions
that require longer time periods.