Designate one of the SAN-attached K2 Summit systems to be the managed device for the entire K2
SAN storage system. Configure a Summit MDI for only that K2 Summit system on the K2 SAN.
If you have multiple standalone K2 Summit systems, multiple K2 SAN systems, or a combination
of standalone and K2 SAN systems, each system must have its own Summit MDI.
When you have multiple Summit MDIs, they must each have their own process port number. For
this purpose, numbers 9160 - 9169 increment in the
Port
field.
Description
Setting or button
The Managed Device Interface (MDI) type to which these settings
apply.
MDI Type
A name for this instance of the MDI type. Do not use spaces in the
MDI name.
MDI Name
The name of the GV STRATUS server that hosts this MDI.
Hostname of device
running the MDI
The process port for this instance of the MDI type. Each instance must
have its own process port. Port numbers must be in range 9160-9169.
Port number
96
GV STRATUS Installation and Service Manual
2013 12 19