SabreTooth Conform Server license process

Only the GV STRATUS server with role of Common Services requires this process.

The Conform license is installed on the GV STRATUS server with role of Common Services.
Typically the GV STRATUS Core server has the role of Common Services.

One STRATUS-CONFORM license is required for each instance of the Conform Engine software
component in your GV STRATUS system. This is a SabreTooth floating license.

If you received your system pre-configured from Grass Valley, licenses are already installed, so
you can skip these tasks. Otherwise, do the following:

1. Refer to the license sheet that you received with your GV STRATUS license. The license sheet

has the Sales Order number that you need.

2. On the GV STRATUS server with role of Common Services, run the SabreTooth License Manager,

generate a unique ID, and send the email to Grass Valley requesting your license or licenses.

Refer to "GV STRATUS Release Notes" for detailed licensing procedures.

3. When you receive your license file, use SabreTooth License Manager and install it on the server.

K2Config Conform Server setup

Only GV STRATUS systems with a Conform Server require this process.

If you received your system pre-configured from Grass Valley, your Conform Server is already set
up on the K2 SAN, so you can skip these tasks. Otherwise, work through the topics in this section
sequentially to add a Conform Server to your online or production K2 SAN.

Related Topics

Synchronizing K2Config information to GV STRATUS Control Panel

on page 229

K2 SAN prerequisites for adding devices

The following K2 SAN preparations are required to support adding a device to the SAN:

All K2 Media Servers and/or K2 RAID storage devices must be installed and cabled.

The control network must be operational with K2 devices communicating. At the command
prompt, use the ping command to verify.

The media network (non-redundant) or networks (redundant) must be operational. You can check
this with the K2Config application.

K2 RAID devices must have disks bound and be configured as required for operation on the K2
SAN.

K2 Media Servers must be configured such that an operational media file system is present.

K2 Ethernet switches must be configured and have V-LANs set up.

The K2 Media Server with role of file system server must be licensed as appropriate for the
design of your K2 SAN.