Commissioning Checklist
Commissioning checklist
Use the following lists to guide the overall task flow of commissioning the system. This
commissioning process assumes you received your system completely set up and configured from
Grass Valley.
Test Grass Valley commissioning
1. Rack, cable, and power on, using the K2 and GV STRATUS System Cabling Guide that shipped
with the system.
2. On a K2 Summit system, open K2 AppCenter and test basic record and play operations.
3. From the control point PC, ping all K2 and GV STRATUS devices to test network connectivity.
If the system has no control point PC, do this test from the GV STRATUS server.
4. In the GV STRATUS application, do the following:
a) In the Navigator, verify access to K2 Summit system bins.
b) Create a Channel Panel and test record/play operations.
c) In the Navigator, select assets on the K2 Summit system.
The assets appear in the Asset List.
d) Double-click an asset in the Asset List.
The asset opens in the Inspector.
e) In the Inspector, verify that the asset has a proxy association.
5. In the Asset List, right-click the high-resolution asset and select
Regenerate Proxy
.
6. Verify the following behavior:
a) In the Inspector, the proxy association is momentarily not visible.
This occurs as the GV STRATUS system deletes the proxy asset.
b) In the Inspector, the proxy association becomes visible again.
This occurs as the Proxy Encoder creates the proxy asset.
If tests succeed, the system is operating correctly, as it did when it left Grass Valley.
Commission customer site
1. Configure the GV STRATUS server on the corporate LAN.
2. Assign GV STRATUS licenses/operations to groups/users.
3. Verify system requirements on GV STRATUS client PCs
4. If any high-resolution GV STRATUS client PCs, make cable connections to control and media
(iSCSI) networks.