Grass Valley GV STRATUS Installation v.3.1 User Manual
Page 424

7. Select the
Video Servers
tab.
8. Right-click and select
Add Server
.
The Edit video server details dialog opens.
9. Fill in the following information:
a) Server Name - Name of the K2 server that the FlashNet server connects to. If applicable,
enter the server name including the
_he0
and
_mxf
suffixes. For MXF archive, the
_mxf
suffix must be at the end of the server name.
NOTE: To archive both GXF and MXF formats from a K2 server, make 2 entries of the
K2 server name with
_he0
suffix for GXF and
_he0_mxf
suffix for MXF.
b) Manufacturer - Select
GVG K2 Series
.
c) Server Type - Select
Video Server
.
d) Top Level Directory - Enter
/GXF
or
/MXF
according to your archive MDI setting.
e) Connection Port - Enter
0
.
NOTE: When you add servers, update those server details in host tables of all devices that
use them. Make sure server names with
_he0
and
_he0_mxf
suffixes are added to your host
tables.
10. Click OK.
The K2 server is added to the FlashNet configuration.
Repeat above steps to add more K2 servers into the configuration.
11. Select the
Cluster Cache
tab, and add the cache path to allow the cleanup and deletion of assets.
12. Launch the FlashNet Storage Manager to continue with the cache cleanup configuration.
13. Select the
Defrag
tab, and set the Defrag Mode to
Perform Defrag And Overwrites
.
424
GV STRATUS Installation and Service Manual
2013 12 19
Complete system set up and configuration