D1000, 4 cooling fans – Yaskawa R1000 Series Power Regenerative Unit User Manual

Page 126

Advertising
background image

6.4 Cooling Fans

126

YASKAWA ELECTRIC TOEP C710656 08B YASKAWA Power Regenerative Unit - R1000 Instruction Manual

Installing the Cooling Fan

Reverse the procedure described above to reinstall the cooling fan.

1.

Properly connect the fan power lines.

2.

Place the power supply connectors and cable back into the recess of the regenerative unit.

Figure 6.9

Figure 6.9 Cooling Fan Power Supply Connectors: 2A0035, 4A0035, 4A0043

3.

Install the replacement fan into the regenerative unit.

Figure 6.10

Figure 6.10 Install the Cooling Fan: 2A0035, 4A0035, 4A0043

4.

Tilt up the back end of the fan finger guard and slide the fan finger guard into the opening near the front of the
regenerative unit, then guide the fan finger guard into place.

Figure 6.11

Figure 6.11 Reattach the Fan Cover: 2A0035, 4A0035, 4A0043

A – Back

B – Front

A

B

Insert the fan at an angle so that it tilts
towards the front of the regenerative
unit. Next press down on the back of
the fan that still protrudes from the
regenerative unit so that the fan snaps
into place.

Insertion area

Front of

regenerative unit

Back of

regenerative unit

Fan finger guard

Back of regenerative unit

Front of unit

Hook

Hook

Cross-Section

D1000

TOEP_C710656_08B_1_0.book 126 ページ 2015年2月5日 木曜日 午前10時7分