General application precautions – Yaskawa R1000 Series Power Regenerative Unit User Manual

Page 14

Advertising
background image

i.2 General Safety

14

YASKAWA ELECTRIC TOEP C710656 08B YASKAWA Power Regenerative Unit - R1000 Instruction Manual

General Application Precautions

Load Capacity

• Install the regenerative unit in one-to-one with a drive. Do not connect the multiple drives to a regenerative unit.
• Connect R1000 to a drive with same maximum applicable motor capacity (Heavy Duty rating [HD]).
• Do not connect regenerative units in parallel.

Selecting the Capacity

Refer to

Table i.1

to select the regenerative unit capacity.

Depending on the amount of regenerated energy, you can select an R1000 with a smaller capacity than the drive.
Use the DriveSelect Inverter Capacity Selection Program to make the selection.
Contact your Yaskawa representative or the nearest Yaskawa sales office.

Table i.1 Model Selection

Install adequate branch circuit short circuit protection per applicable codes.
Failure to comply could result in damage to the regenerative unit.
The regenerative unit is suitable for circuits capable of delivering not more than 100,000 RMS symmetrical Amperes,
240 Vac maximum (200 V Class) and 480 Vac maximum (400 V Class).

Prevent foreign matter such as metal shavings or wire clippings from falling into the regenerative unit during
regenerative unit installation and project construction.
Failure to comply could result in damage to the regenerative unit. Place a temporary cover over the top during

installation. Be sure to remove the temporary cover before start-up, as the cover will reduce ventilation and cause the

regenerative unit to overheat.

Never lift the regenerative unit up while the cover is removed.
This can damage the terminal board and other components.

Do not perform signal checks during operation.
Failure to comply could result in damage to the regenerative unit.

Do not modify the circuitry of the regenerative unit.
Failure to comply could result in damage to the regenerative unit and will void warranty.
Yaskawa is not responsible for any modification of the product made by the user. This product must not be modified.

Do not expose the regenerative unit to halogen group disinfectants.
Failure to comply may cause damage to the electrical components in the regenerative unit.
Do not pack the regenerative unit in wooden materials that have been fumigated or sterilized.
Do not sterilize the entire package after the product is packed.

Drive Capacity or Motor Capacity (HP)

Model

200 V Class

400 V Class

≤ 5

2A03P5

4A03P5

7

2A0005

4A0005

10

2A0007

4A0007

15

2A0010

4A0010

20

2A0014

4A0014

25

2A0017

4A0017

30

2A0020

4A0020

40

2A0028

4A0028

50

2A0035

4A0035

NOTICE