6 digital operator and front cover, Removing/reattaching the digital operator, Removing/reattaching the front cover – Yaskawa R1000 Series Power Regenerative Unit User Manual
Page 47: Digital operator and front cover, Removing the front cover

3.6 Digital Operator and Front Cover
YASKAWA ELECTRIC TOEP C710656 08B YASKAWA Power Regenerative Unit - R1000 Instruction Manual
47
El
ec
tr
ical
I
n
st
al
lat
ion
3
3.6 Digital Operator and Front Cover
NOTICE: Be sure to remove the digital operator prior to opening or reattaching the front cover. Leaving the digital operator plugged into
the regenerative unit when removing the front cover can result in erroneous operation caused by a poor connection. Firmly fasten the
front cover back into place before reattaching the digital operator.
Detach the digital operator from the regenerative unit for remote operation or when opening the front cover to install an
option card.
◆ Removing/Reattaching the Digital Operator
While pressing on the tab located on the right side of the digital operator, pull the digital operator forward to remove it
from the regenerative unit.
Insert the digital operator into the opening in the top cover while aligning it with the notches on the left side of the
opening. Next, press gently on the right side of the operator until it clicks into place.
Figure 3.14
Figure 3.16 Removing/Reattaching the Digital Operator
◆ Removing/Reattaching the Front Cover
■
Removing the Front Cover
Models 2A03P5 to 2A0028, and 4A03P5 to 4A0028
After removing the terminal cover and the digital operator, loosen the screw that affixes the front cover (models 2A03P5
to 2A0007, and 4A03P5 to 4A0007 do not use a screw to affix the front cover). Pinch in on the tabs found on each side of
the front cover, then pull forward to remove it from the regenerative unit.
Figure 3.17 Remove the Front Cover (2A03P5 to 2A0028, 4A03P5 to 4A0028)
Removing
Reattaching
TOEP_C710656_08B_1_0.book 47 ページ 2015年2月5日 木曜日 午前10時7分