2.2 Mechanical Installation

30

YASKAWA ELECTRIC TOEP C710656 08B YASKAWA Power Regenerative Unit - R1000 Instruction Manual

Installation Types and Required Materials

The digital operator mounts to an enclosure two different ways:

• External/face-mount installs the operator outside the enclosure panel
• Internal/flush-mount installs the operator inside the enclosure panel

Table 2.2 Digital Operator Installation Methods and Required Tools

NOTICE: Prevent foreign matter such as metal shavings or wire clippings from falling into the drive or regenerative unit during

installation and project construction. Failure to comply could result in damage to the drive or regenerative unit. Place a temporary cover

over the top of the drive and regenerative unit during installation. Remove the temporary cover before drive and regenerative unit

start-up, as the cover will reduce ventilation and cause the drive or regenerative unit to overheat.

Exterior and Mounting Dimensions

Use

Table 2.3

to find the regenerative unit dimension drawings.

Table 2.3 Models and Types

Installation

Method

<1> If there are welding studs in the control panel, use the Installation Support Set B (for threaded studs).

Description

Installation

Support Sets

Model

Required Tools

External/
Face-Mount

Simplified installation with the
digital operator is mounted on
the outside of the panel with
two screws.

Phillips screwdriver

(#1)

Internal/
Flush-Mount

Encloses the digital operator in
the panel. The front of the
digital operator is flush with
the outside of the panel.

Installation Support Set A

(for mounting with screws through

holes in the panel)

EZZ020642A

Phillips screwdriver

(#1, #2)

Installation Support Set B

(for use with threaded studs that are

fixed to the panel)

<1>

EZZ020642B

Phillips screwdriver (#1)

Wrench (7 mm)

Protective

Design

Regenerative Unit Model

Page

Three-Phase

200 V Class

Three-Phase

400 V Class

IP20/NEMA Type 1 Enclosure

2A03P5
2A0005
2A0007
2A0010
2A0014
2A0017
2A0020
2A0028

4A03P5
4A0005
4A0007
4A0010
4A0014
4A0017
4A0020
4A0028

31

IP00/Open Type Enclosure

2A0035
2A0053
2A0073
2A0105

4A0035
4A0043
4A0053
4A0073
4A0105
4A0150
4A0210
4A0300

32

TOEP_C710656_08B_1_0.book 30 ページ 2015年2月5日 木曜日 午前10時7分