C.4 MEMOBUS/Modbus Setup Parameters
YASKAWA ELECTRIC TOEP C710656 08B YASKAWA Power Regenerative Unit - R1000 Instruction Manual
181
MEMO
BUS/Mod
bus
Co
mmunica
tion
s
C
■
H5-11: Communications Enter Function Selection
Selects whether an Enter command is necessary to change parameter values via MEMOBUS/Modbus communications.
Refer to
.
Setting 0: Enter command necessary
Parameter changes become effective after an Enter command. An Enter command must only be sent after the last
parameter change, not for each single parameter.
Setting 1: Enter command not necessary
Parameter value changes become effective immediately without the need to send an Enter command.
No.
Name
Setting Range
Default
H5-11
Communications Enter Function Selection
0 or 1
1