SV-ADAHRS-200/201 Installation and Configuration

SkyView System Installation Guide – Revision S

5-11

To change which ADAHRS is the PRIMARY ADAHRS, highlight an ALTERNATE ADAHRS and press
the PRIMARY button to elevate it to PRIMARY status.

To disable an ADAHRS until SkyView is next powered up, simply highlight it with the joystick and
press the DISABLE button.

To see the same comparison screen that is presented when a cross-check error occurs, press
the COMPARE button at the bottom of the display.

Press BACK to exit the ADAHRS Source Selection Page or press EXIT to return to the Main Menu.
Either of these actions will save the ADAHRS source settings.

The SkyView system automatically switches to an alternate ADAHRS in the case of a
failure.

Airspeed Limitations

Use the values on this page to set IAS tape colors. Set V-speed (e.g., stall speed in landing
configuration) thresholds on the Airspeed Limitations Page (SETUP MENU > PFD SETUP >
AIRSPEED LIMITATIONS). If your aircraft limitations are expressed in TAS rather than IAS, set
Vne EXPRESSED AS: TAS.

If you do set Vne EXPRESSED AS: TAS, this will affect the Autopilot Pitch Axis MAXIMUM
AIRSPEED.

The values on this page are default values that act as placeholders. You must adjust these
values to work with your aircraft for any colors to show up on the IAS tape and also to be able to
calibrate the autopilot servos.

Vertical Speed Scale

Set the vertical speed scale on the Vertical Speed Scale Page (SETUP MENU > PFD SETUP >
VERTICAL SPEED SCALE).

G Meter

Go to this page (SETUP MENU > PFD SETUP > G METER) to configure the G meter.

The pop-up thresholds are G values that, when exceeded, will cause the G meter to display
automatically. The G meter replaces the HSI when it is displayed. In addition to popping up
automatically, the G meter can be manually toggled on and off using the PFD > G METER
button. If you do not want the G meter to ever be displayed automatically, set the positive pop-
up threshold value very high and the negative pop-up threshold value very low.

You can also set yellow and red cautionary ranges of the G meter here, and whether or not the
max/min recorded Gs are reset at each SkyView boot-up.